Related Experiment Video
Updated: May 16, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Voltammetric platform for detection of 2,4,6-trinitrotoluene based on a molecularly imprinted polymer
M Pesavento1, G D'Agostino, G Alberti
1Dipartimento di Chimica, Università di Pavia, via Taramelli 12, 27100 Pavia, Italy. maria.pesavento@unipv.it
Abstract:
New methods for determination of explosive substances as, for example, 2,4,6-trinitrotoluene (TNT), in a rapid way and at low cost are highly required. An electrochemical platform has been here developed with good characteristics of low dimension, fast response, low cost, and high selectivity. It is based on a commercially available screen printed cell with graphite ink working and auxiliary electrodes and a silver ink quasi-reference electrode. The whole cell is covered with a thick layer of cation exchanging acrylic polymer molecularly imprinted with 2,4,6-trinitrotoluene. The polymeric layer acts at the same time as electrolytic medium and selective receptor. It has been demonstrated that, in this medium, 2,4,6-trinitrotoluene is electroactive at graphite electrode, being reduced by a non-reversible reaction. The peak current (differential pulse voltammogram) is proportional to TNT concentration with limit of detection for TNT around 5 × 10(-7) M and linearity range up to 2 × 10(-5) M. The selectivity for TNT relative to other reducible compounds as, for example, nitroaromatic derivatives, and to other possible interfering substances, as negatively charged ions, is good. Measurements can be performed in not de-aerated solution and in small volumes (20 μl), so that the proposed platform is very promising for in situ determinations.
More Related Videos
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...