Related Experiment Video
Updated: May 16, 2026

11:12
Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
Published on: October 17, 2013
A simple, standard method to characterize pressure/flow performance of vascular access cannulas
Michael J Paulsen1, Ryan Orizondo, Duy Le
1Department of Surgery, University of Michigan Medical School, Ann Arbor, Michigan, USA.
Summary
Selecting extracorporeal life support cannulas is challenging due to limited French size data. The new "UM number" metric simplifies assessment of cannula pressure (P) and flow (Q) performance for easier clinical use.
Area of Science:
- Biomedical Engineering
- Medical Devices
- Fluid Dynamics
Background:
- Vascular access cannulas for extracorporeal life support (ECLS) are sized by French (Fr) units, offering insufficient data on pressure (P) and flow (Q) performance.
- Previous metrics, like the M number, were complex and required nomograms, limiting clinical applicability.
Purpose of the Study:
- To introduce and validate an easier, clinically relevant metric for assessing cannula performance in ECLS.
- To establish the "UM number" (flow at 100 mm Hg P) as a practical standard for cannula selection and performance evaluation.
Main Methods:
- A simulated ECLS circuit with a centrifugal pump, Tygon tubing, and reservoir was utilized.
- Seventy-four cannulas (arterial, venous, double lumen; 6-50 Fr) were tested using a 3 cP glycerol solution to mimic blood viscosity.
- Pressure and flow data were collected using a Biopac system and ultrasonic flow probe across the cannulas' performance range.
Main Results:
- The UM number effectively characterizes the pressure-flow relationship for various cannulas.
- This metric provides a straightforward method for selecting ECLS access cannulas based on desired performance parameters.
- The UM number aids in verifying if actual cannula flow aligns with expected performance during ECLS procedures.
Conclusions:
- The UM number offers a simplified and clinically useful metric for evaluating extracorporeal life support cannula performance.
- Adoption of the UM number can improve the selection process and in-situ monitoring of vascular access cannulas.
- This metric enhances the ability of clinicians to match cannula performance to patient needs in ECLS.
Related Concept Videos
Pipe Flowrate Measurement
In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
The orifice meter is a simple,...
Measurement of Fluid Pressure
Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
