The thermosensitivity of pH/thermoresponsive microspheres activated by the electrostatic interaction of pH-sensitive

Gheorghe Fundueanu1, Marieta Constantin, Ionela Asmarandei

  • 1Department of Bioactive and Biocompatible Polymers, Petru Poni Institute of Macromolecular Chemistry, Iasi 700487, Romania. ghefun@icmpp.ro

Related Concept Videos

Thermosensation01:43

Thermosensation

Peripheral thermosensation is the perception of external temperature. A change in temperature (on the surface of the skin and other tissues) is detected by a family of temperature-sensitive ion channels called Transient Receptor Potential, or TRP, receptors. These receptors are located on free nerve endings. Those detecting cold temperatures are closer to the surface of the skin than the nerve endings detecting warmth. These thermoTRP channels, while temperature selective, have relatively...
Modified-Release Drug Delivery Systems: Stimuli-Activated01:30

Modified-Release Drug Delivery Systems: Stimuli-Activated

Stimuli-activated drug delivery systems are designed to release drugs in response to specific physical, chemical, or biological stimuli. These systems often utilize hydrogels—three-dimensional, hydrophilic polymer networks capable of swelling in aqueous environments and retaining significant fluid volumes. Upon exposure to particular stimuli, these hydrogels undergo structural transitions that allow the embedded drug to be released. Due to this adaptive behavior, such systems are also called...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Microbial Biosensors01:17

Microbial Biosensors

Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...