Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
Published on: January 15, 2013
Integrated-optics-based swept-source optical coherence tomography
V Duc Nguyen1, N Weiss, W Beeker
1Biomedical Engineering & Physics, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands. d.v.nguyen@amc.uva.nl
Abstract:
We designed, fabricated, and characterized an integrated-optics-based swept-source optical coherence tomography (SS-OCT) system in TriPleX technology. An external 1300 nm swept source is coupled to the chip, which contains waveguide structures for interferometric depth ranging and balanced detection. The complete OCT chip has a footprint of 0.4 cm × 1.8 cm. Light from the chip is focused onto the sample using an aspheric lens; the lateral resolution is 21±1 μm. OCT measurements, performed with a moveable mirror, demonstrate a sensitivity of -80 dB and imaging up to the maximum depth of 5.09 mm. Corrected for dispersion, the measured OCT axial resolution of 12.7±0.5 μm is in good agreement with the bandwidth limited resolution. Finally, we demonstrate cross-sectional OCT imaging of a multilayered tissue phantom over the whole depth range with the integrated-optics-based SS-OCT system.
More Related Videos
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
Published on: August 4, 2018
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Total Internal Reflection Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies III: Computed Tomography