Optimal out-of-band correction for multispectral remote sensing
1Remote Sensing Division, Naval Research Laboratory, Washington, DC 20375, USA. wei.chen@nrl.navy.mil
A new optimal out-of-band correction transform (OOBCT) effectively addresses Visible/Infrared Imaging Radiometer Suite (VIIRS) OOB effects. This method significantly reduces spectral radiance errors, outperforming existing techniques for improved remote sensing data accuracy.
Area of Science:
- Remote Sensing
- Optical Physics
- Data Processing
Background:
- Out-of-band (OOB) responses in remote sensing instruments like the Visible/Infrared Imaging Radiometer Suite (VIIRS) can introduce significant errors in spectral radiance measurements.
- Accurate spectral data is crucial for various applications, including environmental monitoring and climate studies.
Purpose of the Study:
- To propose and validate an optimal out-of-band correction transform (OOBCT) specifically designed for onboard VIIRS OOB effects.
- To assess the performance of the OOBCT in correcting spectral radiance measurements, considering only OOB response impacts.
Main Methods:
- The OOBCT matrix is derived by minimizing the summation of errors between expected and realistic recovered band-averaged spectral radiances.
- Numerical computation of the OOBCT matrix utilizes VIIRS filter transmittance functions and simulated hyperspectral data from Airborne Visible InfraRed Imaging Spectrometer (AVIRIS).
- The correction process involves a straightforward matrix multiplication of the OOBCT matrix with the measured multispectral image vector.
Main Results:
- Experimental results using AVIRIS and Hyperspectral Imager for the Coastal Ocean datasets show average errors in recovered spectral radiances are less than 4% of measured radiances.
- The OOBCT method demonstrated superior performance compared to previously reported methods in reducing relative errors across all pixels and bands.
Conclusions:
- The proposed OOBCT provides an effective and straightforward method for correcting onboard VIIRS OOB effects.
- The validated OOBCT method significantly enhances the accuracy of spectral radiance measurements, offering a valuable tool for remote sensing data analysis.
Related Concept Videos
Distance Corrections
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Errors in Global Positioning System
NMR Spectrometers: Resolution and Error Correction
Common Leveling Mistakes and Errors
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2. The spectrum...