Related Experiment Video
Updated: May 16, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Critical airway management: a suggested modification to the rigid fiber-optic stylet based on 301 novice intubations
Yashvir S Sangwan1, Jaime Palomino, Francesco Simeone
1Section of Pulmonary Diseases, Critical Care and Environmental Medicine, Department of Medicine, Tulane University Health Sciences Center, New Orleans, LA, USA. yashvir@ymail.com
Background:
Emergent airways in critically ill patients outside the operating room (critical airways) are often difficult airways frequently managed by intensivists. Current advanced airway management tools have not been adequately evaluated for critical airways and are not specifically designed for intensivists. The rigid fiber-optic stylet has the potential to fill this niche as it is an established difficult intubation technique very similar to bronchoscopy. The purpose of this study was to evaluate the rigid fiber-optic stylet and identify characteristics that would affect its use for critical airway management by intensivists.
Methods:
A retrospective, single-center, observational study was performed in the setting of a tertiary care university teaching hospital. A total of 301 consecutive elective surgery patients underwent endotracheal intubation attempted by a novice using a rigid fiber-optic stylet.
Results:
Novices could successfully intubate >95% patients using the rigid fiber-optic stylet. Most patients were intubated within 2 attempts (93%) in a median time of 73 seconds. In all the cases of intubation failure by novices, the staff anesthesiologist could successfully intubate the patient in his first attempt with an average time of 32 seconds. By studying unsuccessful attempts, we identified an important barrier to the adaptation of this tool for critical airway management-the absence of working channels, which does not allow suctioning, oxygenation, or instillation of lidocaine.
Conclusions:
A multilumen sheath designed with 2 working channels has the potential to overcome all identified barriers to the use of rigid fiber-optic stylet as a critical airway management device by intensivists. This modification should be evaluated in a clinical study.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...

