[Transcutaneous carbon dioxide measurements. Dynamics during hyperventilation in healthy adults]
L Bertram1, S Stiel, M Grözinger
1Abteilung für Palliativmedizin, HSK, Dr. Horst Schmidt Klinik, Ludwig-Erhard-Str. 100, 65199 Wiesbaden, Deutschland. linda.bertram@hsk-wiesbaden.de
Background:
In various fields of medicine the transcutaneous measurement (p(tc)CO₂) of carbon dioxide pressure (pCO₂) has been accepted as a reliable measuring method while for other disciplines the method has been doubted. Nevertheless, some minor therapeutic interventions, such as electroconvulsive therapy and breathing biofeedback used in psychiatry could benefit considerably from transcutaneous monitoring. The study presented here investigated the accuracy of transcutaneous measurement as compared to end-tidal (p(et)CO₂) and capillary (p(cap)CO₂) measurements in hyperventilation.
Methods:
In this study 22 healthy volunteers underwent a hyperventilation procedure with assessment of p(tc)CO₂, p(et)CO₂, p(cap)CO₂, breathing and pulse rates. The three measurement methods of pCO₂ were compared pairwise by Bland-Altman diagrams before and at the end of hyperventilation. The time delay between p(et)CO₂ and p(tc)CO₂ was determined for each individual participant by a stepwise shifting the time course of p(et)CO₂ until an optimal congruence with p(tc)CO₂ was reached.
Results:
The study group consisted of 10 men and 12 women with a mean age of 30.5 ± 9.4 years. The experimental procedure lasted an average of 27.7 min including 1.9 min for the baseline measurement and 11.6 min for the actual hyperventilation procedure. The course of pCO₂ from baseline to the end of the hyperventilation phase and back to normal baseline followed a U-curve in all individuals. The pCO₂ could be reduced by a mean of approximately 45 % for the 3 measurement methods from the individual baseline of 35 mmHg. The breathing and pulse frequencies increased by 26.8 % and 17.3 %, respectively. A total of 91 p(cap)CO₂ values (mean 4 values per person) and 1,218 pairs of p(et)CO₂ and p(tc)CO₂ values (mean 55 values per person) could be evaluated. The difference of the pCO₂ values for two measurement methods revealed similar standard deviations in the Bland-Altman diagrams of about 2.5 mmHg for the 3 pairwise comparisons. The absolute measurement differences between p(et)CO₂ and p(tc)CO₂, p(cap)CO₂ and p(tc)CO₂ as well as p(et)CO₂ and p(cap)CO₂ were averaged for each single participant and afterwards across all individuals resulting in values of 2.0, 2.5 and 2.3 mmHg, respectively. When the baseline and hyperventilation periods were examined separately in this analysis they did not show any relevant differences. The individually determined delays of p(tc)CO₂ in regard to p(et)CO₂ averaged 53 s. The time delay exceeded 1 min in only two study participants.
Conclusions:
In the presented hyperventilation experiment the agreement between the p(tc)CO₂ values and the p(et)CO₂ and p(cap)CO₂ measurements were comparable to the agreement between the latter two. Altogether, the comparability of the measurement methods seemed satisfactory. The delay between the time courses of p(et)CO₂ and p(tc)CO₂ of <1 min for most participants was short and is acceptable for clinical practice. Because only healthy subjects were tested these results might not be the same in children and critically ill patients and could differ from the presented results.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Hyperpnea and Hyperventilation
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...