Related Experiment Video
Updated: May 16, 2026

The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
Thermal imaging of exercise-associated skin temperature changes in trained and untrained female subjects
Damiano Formenti1, Nicola Ludwig, Marco Gargano
1Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via G. Colombo 71, 20133 Milan, Italy. damiano.formenti@unimi.it
Abstract:
Heat dissipation during sport exercise is an important physiological mechanism that may influence athletic performance. Our aim was to test the hypothesis that differences exist in the dynamics of exercise-associated skin temperature changes between trained and untrained subjects. We investigated thermoregulation of a local muscle area (muscle-tendon unit) involved in a localized steady-load exercise (standing heels raise) using infrared thermography. Seven trained female subjects and seven untrained female controls were studied. Each subject performed standing heels raise exercise for 2 min. Thermal images were recorded prior to exercise (1 min), during exercise (2 min), and after exercise (7 min). The analysis of thermal images provided the skin temperature time course, which was characterized by a set of descriptive parameters. Two-way ANOVA for repeated measures detected a significant interaction (p = 0.03) between group and time, thus indicating that athletic subjects increased their skin temperature differently with respect to untrained subjects. This was confirmed by comparing the parameters describing the speed of rise of skin temperature. It was found that trained subjects responded to exercise more quickly than untrained controls (p < 0.05). In conclusion, physical training improves the ability to rapidly elevate skin temperature in response to a localized exercise in female subjects.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
