Contrast enhanced lung MRI in mice using ultra-short echo time radial imaging and intratracheally administrated Gd-DOTA-based nanoparticles
Related Experiment Video
Updated: May 16, 2026

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
Andrea Bianchi1, François Lux, Olivier Tillement
1Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Université Bordeaux Segalen, Bordeaux, France.
Purpose:
To investigate the in vivo T1 -enhancement of the lung parenchyma in free-breathing healthy mice following intratracheal administration of Gd-DOTA-based nanoparticles, to assess the enhancement kinetics of the instilled contrast medium and to identify its elimination pathways.
Methods:
Ultrashort Echo Time (276 μs) proton MRI of the lung was performed (N = 14) at 4.7 T after the intratracheal instillation of 50 μL of seven different concentrations of contrast agent solution (from 2 to 100 mM of Gd(3+) ). The signal enhancement (SE) in lungs, blood, liver, kidneys, and bladder was assessed (N = 3) for a 50 mM concentration solution at different time points.
Results:
The largest SE in lungs (266 ± 14%) was observed for a 50 mM solution of Gd(3+) . In lungs, the SE was observed to decay exponentially with a time constant of 149 ± 51 min. The passage of the nanoparticles from lung tissue to blood and kidneys, and ultimately to the bladder, was observed. No significant hepatic enhancement was measured.
Conclusion:
This study demonstrates the feasibility of large SEs of lung tissue using intratracheally administrated solutions of Gd-based contrast agents. In future applications, the SE in lungs could be used to image the biodistribution of coadministrated drug aerosols or to selectively enhance lung diseased tissues.