Related Experiment Video
Updated: May 16, 2026

Building Langmuir Probes and Emissive Probes for Plasma Potential Measurements in Low Pressure, Low Temperature Plasmas
Published on: May 25, 2021
Arrays of low-temperature plasma probes for ambient ionization mass spectrometry
Jon K Dalgleish1, Michael Wleklinski, Jacob T Shelley
1Department of Chemistry, Purdue University, West Lafayette, IN 47907-2084, USA.
Rationale:
This paper reports the development of arrays of capillary-based low-temperature plasma (LTP) probes for direct sample analysis. These probe arrays allow a higher surface area to be analyzed, increasing the throughput in large sample analysis. Validation of these arrays was performed on illicit, cathinone-based drugs marketed as 'bath salts'.
Methods:
LTP arrays consisting of 1, 7, and 19 probes were constructed with quartz capillaries and held together with silver epoxy resin adhesive. Three drugs, mephedrone, methylone and methylenedioxypyrovalerone, were analyzed with each plasma ion source and an ion trap mass spectrometer in full MS and in MS/MS positive ion mode. Chemical and thermal footprints were determined for each source. A reactive probe design was used to inject trifluoroacetic anhydride directly into the plasma stream for on-line derivatization.
Results:
Small LTP probes and bundled arrays provide low picogram level limits of detection for mephedrone, methylone and methylenedioxypyrovalerone. Bundling the probes together in larger arrays increases the surface area analyzed by a factor of ten, while maintaining surface temperatures below 40 °C. Selectivity towards mephedrone and methylone was increased using trifluoracetylation under ambient ionization conditions.
Conclusions:
Low-temperature plasma ionization sources allow rapid detection of illicit 'bath salt' drugs in low amounts. The sources have a larger sampling area that allows faster detection of each analyte, and selectivity towards the selected drug is enhanced by adding reagents directly into the plasma stream.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Mass Analyzers: Common Types
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.