Related Experiment Video
Updated: May 15, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Primary and revision THA using a stemless metaphyseal-loading implant above distorted proximal femoral anatomy
Peter S Young1, Rory G Middleton, Nijil L Vasukutty
1Department of Orthopaedics and Trauma, Pilgrim Hospital, Boston, UK. peteryoung2@nhs.net
Abstract:
Total hip arthroplasty is well established as a successful treatment for end stage arthritis, with a wide variety of components currently available. Using traditional stemmed implants in patients with a distorted proximal femur can be technically challenging with an increased risk of complications. We present seven patients with distorted proximal femoral anatomy or failed hip arthroplasty in whom a short, metaphyseal loading implant was utilised. At minimum two-year follow-up there have been no complications with all stems stable and well fixed radiologically. Average improvement in Oxford Hip Score is 32. We suggest that a short, metaphyseal loading prosthesis can be considered in cases where a conventional stemmed implant may not be suitable due to challenging proximal femoral anatomy.