Related Experiment Video
Updated: Oct 1, 2025

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Dual mobility hip arthroplasty: iatrogenic intraprosthetic dislocation of a 22 mm head
Mate Zabaglo1, Haider Merchant2, Paul Haggis2
1T&O, Royal Cornwall Hospitals NHS Trust, Truro, Cornwall, UK mate.zabaglo@nhs.net.
Abstract:
We describe the first intraprosthetic dislocations of a 22 mm head in a dual mobility hip replacement in the literature. This case emphasises the importance of information gathering and planning when dealing with arthroplasty complications. Furthermore, it highlights the necessity of adequate muscle relaxation and analgesia when dealing with hip dislocations. A 78-year-old patient presented to the emergency department (ED) with a spontaneous dislocation of her left dual-mobility total hip replacement 3 months after first-stage revision surgery for infection. Reduction via manipulation under analgesia was then attempted in the ED but was ultimately unsuccessful; an iatrogenic intraprosthetic dislocation of the polyethylene liner was sustained. Several factors may have contributed to liner dislocation: a failure to appreciate the implant type, multiple manipulations in ED were attempted under analgesia, but no sedation or muscle relaxation was administered to the patient. The patient subsequently underwent revision surgery.