Acetic acid detection threshold in synthetic wine samples of a portable electronic nose

Miguel Macías Macías1, Antonio García Manso, Carlos Javier García Orellana

  • 1University Center of Merida, University of Extremadura, Sta. Teresa de Jornet, 38, Mérida 06800, Spain. miguel@nernet.unex.es

Related Concept Videos

Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
Titration of a Weak Acid with a Strong Base01:30

Titration of a Weak Acid with a Strong Base

In titrating a weak acid with a strong base, different calculation methods are applied at various stages. Initially, the pH of a weak acid like acetic acid is calculated using its dissociation constant (Ka) and an ICE table. Upon addition of a strong base such as sodium hydroxide, a buffer forms, and its pH is determined using the Henderson-Hasselbalch equation. As more base is added and the titration reaches the halfway point, the pH becomes equal to the pKa of the acid, indicating equal...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
IR and UV–Vis Spectroscopy of Carboxylic Acids01:28

IR and UV–Vis Spectroscopy of Carboxylic Acids

In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...