Related Experiment Video
Updated: May 15, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Controversies about effects of low-kilovoltage MDCT acquisition on Agatston calcium scoring
Fabrice C Deprez1, Alain Vlassenbroek, Benoît Ghaye
1Department of Medical Imaging, Cliniques Universitaires St Luc, Université Catholique de Louvain, Avenue Hippocrate 10, 1200 Brussels, Belgium. fabrice-deprez@uclouvain.be
Abstract:
Recent articles have advocated the possibility of obtaining Agatston coronary calcium scoring at 100 kVp by using a single adapted elevated calcium threshold. To evaluate the influence of kilovoltage potential protocols on the Agatston score, we acquired successive scans of a calcium scoring phantom at 4 levels of kilovoltage potential (80, 100, 120, and 140 kVp, 55 mAs) and measured semiautomatically the individual and the total Agatston score of 6 inserts (of 5-mm and 3-mm diameter) containing hydroxyapatite at different concentrations (800, 400, 200 mg/cm(3)). Our results showed that Agatston scores obtained at various low-kilovoltage potential protocols can be highly overestimated in some particular cases. At 80 kVp, for example, mean measured Agatston score was multiplied by a factor from 1.06 (5-mm highest density insert) to 2.67 (3-mm lowest density insert) compared with the Agatston scores performed at 120 kVp. Indeed in the one hand, reducing kilovoltage potential in multidetector CT acquisitions increase the CT density of coronary calcifications that can be measured on the reconstructed images. On the other hand, Agatston score is a multi-threshold measurement (with a step weighting function). Consequently low kilovoltage potential can lead to overweight some calcifications scores. For these reasons, Agatston score with low kilovoltage potential acquisition cannot be reliably adapted by a unique recalibration of the standard calcium attenuation threshold of 130 HU and requires a standardized CT acquisition protocol at 120 kVp. Alternatives to performing low-dose coronary artery calcium scans are either using coronary calcium scans with reduced tube current (low mAs) at 120 kVp with the iterative reconstructions or using mass/volume scoring (not influenced by kilovoltage potential variations). Finally, we emphasized that incorrect Agatston score evaluation may have important clinical, financial, and health care implications.
More Related Videos
06:57Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
08:02Novel Quantification Protocol for Cardiovascular Calcification Progression Using Longitudinal MicroPET/MicroCT Images
Published on: November 15, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...