Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Perturbationless calibration of pulse transit time to blood pressure
Mingwu Gao1, Ramakrishna Mukkamala
1Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA. gaomingw@msu.edu
Abstract:
Pulse transit time (PTT) often shows strong correlation with blood pressure (BP) and may therefore represent a means for achieving continuous, non-invasive, and cuff-less BP monitoring. However, construction of the subject-specific curve needed to calibrate PTT to BP conventionally requires simultaneous measurements of PTT and BP during an experimental perturbation that varies BP over a significant range. We propose a technique for perturbationless calibration of PTT to BP. This technique constructs the calibration curve from central and peripheral BP waveforms by exploiting the natural pulsatile variation in the waveforms via a nonlinear tube-load model. We conducted initial testing of the technique in animals by applying it to the waveforms during a baseline period and then predicting mean BP during subsequent major hemodynamic interventions via PTT calibrated with the resulting curve. The bias in the mean BP error was 4.9 mmHg, while the precision in this error was 7.6 mmHg.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: