Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
The comparison of a novel continuous cardiac output monitor based on pulse wave transit time and echo Doppler during
Yoshihiro Sugo1, Tomoyuki Sakai, Mami Terao
1Nihon Kohden Corp., 1-31-4 Nishi-Ochiai, Shinjuku-ku, Tokyo, Japan. Yoshihiro_Sugo@mb4.nkc.co.jp
Abstract:
A new technology called estimated continuous cardiac output (esCCO) uses pulse wave transit time (PWTT) obtained from an electrocardiogram and pulse oximeter to measure cardiac output (CO) non-invasively and continuously. This study was performed to evaluate the accuracy of esCCO during exercise testing. We compared esCCO with CO measured by the echo Doppler aortic velocity-time integral (VTIao_CO). The correlation coefficient between esCCO and VTIao_CO was r= 0.87 (n= 72). Bias and precision were 0.33 ± 0.95 L/min and percentage error was 31%. The esCCO could detect change in VTIao_CO larger than 1 L/min with a concordance rate of 88%. In polar plot, 83% of data are within 0.5 L/min, and 100% of data are within 1 L/min. Those results show the acceptable accuracy and trend ability of esCCO. Change in pre-ejection period (PEP) measured by using M-mode of Diagnostic Ultrasound System accounted for approximately half of change in PWTT. This indicates that PEP included in PWTT has an impact on the accuracy of esCCO measurement. In this study, the validity of esCCO during exercise testing was assessed and shown to be acceptable. The result of this study suggests that we can expand its application.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...