Related Experiment Video
Updated: May 14, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Low-density solvent-based dispersive liquid-liquid microextraction combined with single-drop microextraction for the
Xiaoyi Li1, Aifang Xue, Hao Chen
1College of Science, Huazhong Agricultural University, Wuhan 430070, China.
Abstract:
A new format of fast three-phase microextraction by combining low-density solvent-based dispersive liquid-liquid microextraction (DLLME) and single-drop microextraction (SDME) was for the first time developed for the determination of chlorophenols in environmental water samples. The extraction procedure includes a 2 min DLLME pre-extraction and a 10 min SDME back-extraction. A portion of low-density solvent (toluene) was used as organic phase and injected into the aqueous sample (donor phase) with methanol as disperser. The analytes were pre-extracted into the organic phase within 2 min. A thin layer of the organic phase formed on the top of the aqueous phase by a 2 min centrifugation. Then a drop of acceptor solution was introduced into the upper layer and SDME was carried out for the back-extraction. The stirring step typically involved in SDME and LLLME is avoided with the benefit of the high speed and efficiency of DLLME pre-extraction. After extraction, the acceptor drop was withdrawn and directly injected into a high performance liquid chromatography instrument with ultraviolet detection for analysis. Five chlorophenols, 4-chlorophenol, 2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, and pentachlorophenol, were selected as model compounds for developing and evaluating the method. Factors affecting extraction efficiency were studied, including the organic solvent, the disperser solvent, the composition of donor phase and acceptor phase, the volume of acceptor microdrop, and the extraction time. At optimal conditions, the method showed low detection limit (0.016-0.084 μg/L) for the five chlorophenols, good linearity (from 0.2-250 to 1.0-250 μg/L, depending on the analytes) and repeatability (RSD below 8.2, n=5). The simple, fast, and efficient feature of the proposed method was demonstrated by the analysis of chlorophenols in environmental water samples.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...

