A multidimensional micro gas chromatograph employing a parallel separation multi-column chip and stop-flow μGC × μGCs
Bo-Xun Chen1, Te-Yu Hung, Rih-Sheng Jian
1Chemistry Department, National Taiwan Normal University, Ting-Chow Rd., Taipei, Taiwan.
Abstract:
A dual-chip, multidimensional micro gas chromatographic module was designed, built and evaluated. Column chips were fabricated on a silicon wafer with an etched rectangular channel 100 μm (width) × 250 μm (depth) using a deep reactive ion etching (DRIE) process. The column chip for the first GC dimension was 3 m long and was coated with polydimethylsiloxane (DB-1) as the stationary phase. The columns on the second dimensional chip were etched with the same width and depth as the first chip, but the flow channel was split into three parallel columns, 1 m long, on the same sized silicon chip (i.e., 3 cm × 3 cm). These three parallel columns on the second chip were coated with polyethylene oxide (DB-Wax), trifluoropropylpolymethylsilicone (OV-210) and cyanopropylmethylphenylmethylpolysilicone (OV-225), accordingly, in order to provide diversified chromatographic retention. These two chips were connected via a stop-flow configuration to simultaneously generate multiple two-dimensional gas chromatograms for every analysis. This stop-flow μGC × μGCs design allowed the first column to function as a pre-separator and as a sequencing injector for the second parallel-separation chip. Fifteen volatile organic compounds with boiling points that ranged from 80-131 °C with various functional groups were tested using this μGC × μGCs module. Three discrete 2-D chromatograms were generated simultaneously, which demonstrated the advantages of simultaneously combining GC × GC with parallel separation GCs in microchip chromatography. The total traveling length in the column was only 4 m for each eluted peak and fully resolved separation was achieved through the cross reference among triplet 2-D chromatograms.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...