Related Experiment Video
Updated: May 14, 2026

Detection of Intracellular Gene Expression in Live Cells of Murine, Human and Porcine Origin Using Fluorescence-labeled Nanoparticles
Published on: November 13, 2015
A lateral flow biosensor for the detection of human pluripotent stem cells
Wei Wu1, Luxin Yu, Zhiyuan Fang
1Key Laboratory of Regenerative Biology, South China Institute for Stem Cell Biology and Regenerative Medicine, Guangzhou Institutes of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou 510530, China.
Abstract:
A lateral flow biosensor based on immunoassay has been developed for the detection of human stem cells for the first time. Antibody specific for a human stem cell surface antigen, SSEA-4, is coated onto gold nanoparticles, whereas antibody against another human pluripotent stem cell surface antigen, SSEA-3, is immobilized on the test zone of the NC membrane. Target cells bind to the antibody coated on the gold nanoparticles to form nanoparticles-stem cell complexes, and the complexes are then captured by another antibody immobilized on the test zone to form a red line for visual detection. This biosensor has been successfully applied to human embryonic stem cells and induced pluripotent stem cells. It is capable of detecting a minimum of 10,000 human embryonic stem cells by the naked eye and 7000 cells with a portable strip reader within 20 min. This approach has also shown excellent specificity to distinguish other types of cells. The biosensor shows great promise for specific and handy detection of human pluripotent stem cells.