Related Experiment Video
Updated: May 13, 2026

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Comparative analysis of intraocular lens power calculation methods after excimer laser surgery
Ivan Alcorta Toro1, Graciela Blanco, Antolin Losada Rodriguez
1Centro Oftalmologico Pasteur, Department of Ophthalmolo gy, Clinica Santa Maria, Santiago de Chile, Chile. ialcorta@vtr.net
Abstract:
Many methods have been used in an attempt to more accurate predict the intraocular lens (IOL) power in the eyes undergoing refractive surgery, but none has proved most accurate. The aim of this study was to evaluate the accuracy and predictability of different IOL power calculation methods in eyes after excimer laser surgery. The outcomes of phacoemulsification and IOL implantation in 18 eyes of 16 patients with prior excimer laser keratectomy were documented. The lowest error was achieved using history-derived method. The refractive results of IOL implantation using the same biometry data in eyes after excimer laser surgery can vary markedly. In the present study, the SRK-T formula resulted in highest accuracy.