Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Nonlinear alignment of chromatograms by means of moving window fast Fourier transfrom cross-correlation
Zhong Li1, Jia-Jun Wang, Jing Huang
1Yunnan Academy of Tobacco Science, Kunming, PR China.
Abstract:
The preprocessing of chromatograms is essential to modern chromatography for further qualitative and quantitative analysis, especially when chromatographic instruments are used for herb products analysis involving large number of samples. To accurately compare and analyze the obtained chromatograms, it is necessary to preprocess, especially align retention time shifts. Here moving window fast Fourier transform (FFT) cross-correlation is introduced to perform nonlinear alignment of high-throughput chromatograms. Since elution characteristics of chromatograms will produce local similarity in retention time shifts, moving window procedure seems to be a better substitute of segmentation steps. The retention time shifts can be calculated and accelerated by FFT cross-correlation. The artifacts can be detected and eliminated from the retention time shifts profile since the continuity of moving window procedure. The proposed method is demonstrated in comparison with recursive alignment by FFT on chromatographic datasets from herb products analysis. It is shown that the proposed method can address nonlinear retention time shift problem in chromatograms with the simple moving window procedure, which will not introduce segments size optimization problem. In additional, the parameters are intuitive and easy to adjust, which makes it off-the-shelf toolbox for alignment of chromatograms.
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the lowest drug...
2D NMR: Overview of Heteronuclear Correlation Techniques
Affinity Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...