Related Experiment Video
Updated: May 13, 2026

Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
Highly sensitive analysis of four hemeproteins by dynamically-coated capillary electrophoresis with chemiluminescence
Zian Lin1, Xiaobo Sun, Yao Lin
1Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China. zianlin@fzu.edu.cn
Abstract:
Dynamic coating of the surface in capillary electrophoresis with chemiluminescence detection (CE-CL) using an off-column coaxial flow interface for the determination of four hemeproteins was developed. This method is based on the luminol-hydrogen peroxide reaction catalyzed by metalloproteins in alkaline medium. The experimental setup of the CE-CL system with the proposed off-column coaxial interface was evaluated by separation and detection of dopamine and catechol based on inhibition of the luminol-potassium ferricyanide reaction. Highly efficient separation of the two model compounds with symmetrical peak shape and satisfactory reproducibility was achieved by using this interface. In addition, in order to obtain a good resolution for hemeproteins, polyvinylpyrrolidone (PVP) combined with sodium dodecyl sulfate (SDS) were introduced as dynamic modifiers to reduce the unwanted adsorption of non-specific protein. Several parameters affecting the CE separation and CL detection were investigated in detail. Under the optimized conditions, a mixture of the four hemeproteins (horseradish peroxidase (HRP), catalase (Cat), myoglobin (Mb) and cytochrome C (Cyt C)) could be well separated within 20 min. The linear ranges of the four proteins were 5.7 × 10(-8) to 1.1 × 10(-6) mol L(-1) for HRP, 4.0 × 10(-8) to 2.0 × 10(-6) mol L(-1) for Cat, 1.1 × 10(-10) to 5.6 × 10(-8) mol L(-1) for Mb, and 3.8 × 10(-7) to 7.7 × 10(-6) mol L(-1) for Cyt C. The limits of detection (LODs) (S/N = 3) for HRP, Cat, Mb and Cyt C were 2.2 × 10(-8) mol L(-1) (104.5 amol), 1.6 × 10(-8) mol L(-1) (74 amol), 5.6 × 10(-11) mol L(-1) (0.26 amol), and 1.95 × 10(-7) mol L(-1) (0.89 fmol), respectively. The proposed method has been successfully applied to the analysis of low-level Mb in a spiked human urine sample and the recoveries were above 97%. Our primary result demonstrated that the proposed CE-CL method has great potential for Mb determination in clinical diagnosis.
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
