Related Experiment Video
Updated: May 13, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Effect of enhanced external counterpulsation depends on arterial compliance
1Department of Internal Medicine, Region Hospital, Herning, Denmark. asheft@rm.dk
Abstract:
Enhanced external counterpulsation (EECP) is a non-invasive therapy offered to patients with refractory angina pectoris. Previous studies have demonstrated that its clinical effect depends on the diastolic/systolic augmentation ratio (D/S ratio). We hypothesized that the D/S ratio is associated with arterial stiffness measured as pulse wave velocity (PWV) and brachial pulse pressure (PP). Twenty patients with known refractory angina (17 men, 3 women; mean age 64 years) were included and underwent one hour of EECP treatment (Vasomedical Inc., Westbury, NY, USA). Three sets of cuffs were applied around the lower extremities. Gated by electrocardiography (ECG), air was inflated in diastole at a pressure of 260 mmHg and deflated at the start of systole. The D/S ratio was monitored with finger plethysmography. Carotid-femoral pulse wave velocity (PWV) was measured with mechanotransducers (Complior SP, Artech Medical, France). PWV and brachial BP were measured at baseline before EECP. The mean (SD) BP was 140 (23.5)/77 (9.9) mmHg, PP 62.8 (18.3) mmHg and PWV 10.8 (4.4) m/s. EECP treatment increased the D/S ratio during a one-hour session compared with baseline (1.30 (0.11) vs. 0.56 (0.04) P < 0.001), and the D/S ratio at 45 min. was significantly correlated with PWV (r = 0.49, P < 0.05) and PP (r = 0.58, P < 0.05). We demonstrated that the diastolic augmentation (D/S ratio) during EECP treatment depends on arterial stiffness. The results suggest that arterial compliance has a crucial influence on the effect of EECP and that large-artery stiffness may reduce the effect of EECP.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection

