Related Experiment Video
Updated: May 13, 2026

Imaging CD19+ B Cells in an Experimental Autoimmune Encephalomyelitis Mouse Model using Positron Emission Tomography
Published on: January 20, 2023
Serial non-invasive assessment of antibody induced nephritis in mice using positron emission tomography
Guiyang Hao1, Yong Du, Xin J Zhou
1Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, United States of America.
Mouse models of experimental anti-glomerular basement membrane (anti-GBM) nephritis provide an analytical tool for studying spontaneous lupus nephritis. The potential of Positron Emission Tomography (PET) was evaluated using 2-deoxy-2-[(18)F]fluoro-d-glucose (FDG) as a probe to monitor the progression of anti-GBM induced nephritis in a mouse model. The imaging results were compared to conventional measures of renal function and pathological changes. Serum and urinary vascular cell adhesion molecule-1 (VCAM-1) levels were used as measures of endothelial cell activation and inflammation. Following a challenge with anti-glomerular antibodies, mice exhibited peak changes in serum creatinine, proteinuria, and glomerulonephritis score at 14 days post-challenge (p.c.). In contrast, VCAM levels peaked at day 7 p.c. On dynamic PET images (0-60 min) of day 7, kidneys of the anti-GBM nephritis mice demonstrated a unique pattern of FDG uptake. Compared to the time activity curve (TAC) prior to challenge, a rightward shift was observed after the challenge. By day 10 p.c., kidney FDG uptake was lower than baseline and remained so until the study ended at 21 days p.c. During this time frame measures of renal dysfunction remained high but VCAM-1 levels declined. These changes were accompanied by an increase in kidney volume as measured by Computed Tomography (CT) and intra-abdominal fluid collection. Our results suggest that FDG-PET-CT can be used as a non-invasive imaging tool to longitudinally monitor the progression of renal disease activity in antibody mediated nephritis and the magnitude of renal FDG retention correlates better with early markers of renal inflammation than renal dysfunction.
Mouse models of experimental anti-glomerular basement membrane (anti-GBM) nephritis provide an analytical tool for studying spontaneous lupus nephritis. The potential of Positron Emission Tomography (PET) was evaluated using 2-deoxy-2-[(18)F]fluoro-d-glucose (FDG) as a probe to monitor the progression of anti-GBM induced nephritis in a mouse model. The imaging results were compared to conventional measures of renal function and pathological changes. Serum and urinary vascular cell adhesion molecule-1 (VCAM-1) levels were used as measures of endothelial cell activation and inflammation. Following a challenge with anti-glomerular antibodies, mice exhibited peak changes in serum creatinine, proteinuria, and glomerulonephritis score at 14 days post-challenge (p.c.). In contrast, VCAM levels peaked at day 7 p.c. On dynamic PET images (0-60 min) of day 7, kidneys of the anti-GBM nephritis mice demonstrated a unique pattern of FDG uptake. Compared to the time activity curve (TAC) prior to challenge, a rightward shift was observed after the challenge. By day 10 p.c., kidney FDG uptake was lower than baseline and remained so until the study ended at 21 days p.c. During this time frame measures of renal dysfunction remained high but VCAM-1 levels declined. These changes were accompanied by an increase in kidney volume as measured by Computed Tomography (CT) and intra-abdominal fluid collection. Our results suggest that FDG-PET-CT can be used as a non-invasive imaging tool to longitudinally monitor the progression of renal disease activity in antibody mediated nephritis and the magnitude of renal FDG retention correlates better with early markers of renal inflammation than renal dysfunction.
More Related Videos
07:45Preclinical Positron Emission Tomography with Body Conforming Animal Molds for Cloud-Based Automated Image Analysis in Mice
Published on: October 25, 2024
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET