Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
The predictive value of Muller's maneuvre for CPAP titration in OSAHS patients
Marcello Bosi1, Andrea De Vito, Claudio Vicini
1Thoracic Diseases Department, Morgagni-Pierantoni Hospital, Forli, Italy.
Abstract:
To investigate the role of awake upper airways (UA) endoscopy assessment as a parameter of prediction for CPAP titration in OSAHS patient therapy. Retrospective analysis of UA endoscopic assessment with Mueller's maneuvre and the application of the nose oropharynx hypopharynx score (NOHs) was conducted to obtain a numeric score representing the grade of severity of UA obstruction. Other commonly used predictive parameters for CPAP titration were also included in the study: anthropometric [BMI, neck circumference (NC)] and polysomnographic parameters (AHI, ODI). 3 groups of patients were identified: (1) 67/90 patients requiring intermediate CPAP values, (2) 13/90 patients requiring high CPAP values, and (3) 10/90 patients requiring low pressure values. BMI (p = 0.0013) was the only monitored parameter to show significant statistical value as a CPAP titration predictor. However, higher values of anthropometric parameters (NOHs ≥9, BMI >35, NC >45) showed a sensitivity of 69.2% as a single parameter and 76.9% as combined parameters, and specificity between 66.2 and 72.7% as a single parameter and 43.4% as combined parameters, unequivocally identifying patients requiring high therapeutic CPAP value. A lower cut-off of anthropometric parameters (NOHs ≤6, BMI ≤29, NC <42) showed sensitivity between 40 and 60% as a single parameter and of 90% as combined parameters, and specificity between 68.7 and 80.2% as a single parameter which increased to 93.7% as combined parameters, identifying patients requiring a low therapeutic CPAP value. The results show that anthropometric and polygraphic parameters have no significant independent predictive value for CPAP titration, with the exception of BMI. However, anthropometric parameters showed good levels of sensitivity and specificity in OSAHS patients requiring high or low levels of CPAP therapy.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...