Background:
Hyperglycemia due to increase in insulin resistance (IR) is often observed after surgery in spite of normal insulin secretion. To evaluate the degree of IR, the golden standard method is the normoglycemic hyperinsulinemic clamp technique (glucose clamp: GC). The GC using the artificial pancreas, STG-22 (Nikkiso, Tokyo, Japan), was established as a more reliable method, since it was evaluated during steady-state period under constant insulin infusion. Homeostasis model assessment insulin resistance (HOMA-IR), however, is frequently employed in daily practice because of its convenience. We, therefore, investigated the reliability of HOMA-IR in comparison with the glucose clamp using the STG-22.
Methods:
Eight healthy patients undergoing maxillofacial surgery were employed in this study after obtaining written informed consent. Their insulin resistance was evaluated by HOMA-IR and the GC using the STG-22 before and after surgery.
Results:
HOMA-IR increased from 0.81 +/- 0.48 to 1.17 +/- 0.50, although there were no significant differences between before and after surgery. On the other hand, M-value by GC significantly decreased after surgery from 8.82 +/- 2.49 mg x kg(-1) x min(-1) to 3.84 +/- 0.79 mg x kg(-1) x min(-1) (P = 0.0003). In addition, no significant correlation was found between the values of HOMA-IR and the M-value by GC.
Conclusions:
HOMA-IR may not be reliable to evaluate IR for perioperative period.