Flexible high-order QAM transmitter using tandem IQ modulators for generating 16/32/36/64-QAM with balanced

Guo-Wei Lu1, Takahide Sakamoto, Tetsuya Kawanishi

  • 1National Institute of Information and Communications Technology (NICT), 4-2-1 Nukui-Kitmachi, Koganei, Tokyo 184-8795, Japan.gwlu@nict.go.jp

Optics Express
|March 14, 2013
PubMed

Related Concept Videos

Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Design Example: Capacitance Multiplier Circuit01:20

Design Example: Capacitance Multiplier Circuit

In integrated circuit technology, a capacitance multiplier is often utilized to produce a larger capacitance value when a small physical capacitance falls short. This is achieved by a circuit that multiplies capacitance values by a factor of up to 1000, such that a 10-pF capacitor can replicate the performance of a 100-nF capacitor.
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.
Design Example01:23

Design Example

The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...