Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Supporting Medication Adherence and Patient-Centered Care for Attention-Deficit Hyperactivity Disorder in Taiwan: A Pharmacist-Oriented Perspective Informed by Targeted Evidence.

Patient preference and adherence·2026
Same author

DNMT1 deficiency promotes pulmonary vascular remodeling in pulmonary hypertension through epigenetic upregulation of BMP7.

Respiratory research·2025
Same author

Three-dimensional forward-scattering imaging flow cytometry system for single-cell analysis.

APL photonics·2025
Same author

Recent Progress in Cathode Materials for Ca-Ion Batteries.

Advanced materials (Deerfield Beach, Fla.)·2025
Same author

Chemoresistive and Catalytic Dual-Signal Pd-WO<sub>3</sub> MEMS Sensor for Reliable H<sub>2</sub> Monitoring.

Small (Weinheim an der Bergstrasse, Germany)·2025
Same author

Synergistic Suppression of Jahn-Teller Distortion in P2-Type Li/Mn Cathodes by Fe Substitution and Increased Na Content.

Small (Weinheim an der Bergstrasse, Germany)·2025
Same journal

Tunable self-assembling cellular microarray for single-neutrophil vital and suicidal extracellular traps.

Lab on a chip·2026
Same journal

Precise programmable tumor cell subpopulation sorting <i>via</i> an electromagnetic microfluidic platform.

Lab on a chip·2026
Same journal

Bridging dimensions: combining one- and two-photon 3D printing for microfluidic device fabrication.

Lab on a chip·2026
Same journal

Microfluidic rare cell analysis beyond counting: workflow design from enrichment to multi-omics.

Lab on a chip·2026
Same journal

A sperm racetrack to separate sperm by swim speed.

Lab on a chip·2026
Same journal

Controlled encapsulation and droplet size prediction in two-step microfluidic double emulsions.

Lab on a chip·2026
See all related articles

Related Experiment Video

Updated: May 13, 2026

Generation of Size-controlled Poly (ethylene Glycol) Diacrylate Droplets via Semi-3-Dimensional Flow Focusing Microfluidic Devices
11:08

Generation of Size-controlled Poly (ethylene Glycol) Diacrylate Droplets via Semi-3-Dimensional Flow Focusing Microfluidic Devices

Published on: July 3, 2018

Universally applicable three-dimensional hydrodynamic microfluidic flow focusing.

Yu-Jui Chiu1, Sung Hwan Cho, Zhe Mei

  • 1Materials Science Program, University of California at San Diego, La Jolla, California 92093-0418, USA. fenixroger@gmail.com

Lab on a Chip
|March 16, 2013
PubMed
Summary
This summary is machine-generated.

This study presents a novel microfluidic device for precise 3D particle focusing, significantly improving cell confinement and velocity measurements for applications like flow cytometry and fluorescence-activated cell sorting (FACS).

More Related Videos

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets
08:20

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets

Published on: February 22, 2016

Fabrication and Operation of Acoustofluidic Devices Supporting Bulk Acoustic Standing Waves for Sheathless Focusing of Particles
10:14

Fabrication and Operation of Acoustofluidic Devices Supporting Bulk Acoustic Standing Waves for Sheathless Focusing of Particles

Published on: March 6, 2016

Related Experiment Videos

Last Updated: May 13, 2026

Generation of Size-controlled Poly (ethylene Glycol) Diacrylate Droplets via Semi-3-Dimensional Flow Focusing Microfluidic Devices
11:08

Generation of Size-controlled Poly (ethylene Glycol) Diacrylate Droplets via Semi-3-Dimensional Flow Focusing Microfluidic Devices

Published on: July 3, 2018

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets
08:20

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets

Published on: February 22, 2016

Fabrication and Operation of Acoustofluidic Devices Supporting Bulk Acoustic Standing Waves for Sheathless Focusing of Particles
10:14

Fabrication and Operation of Acoustofluidic Devices Supporting Bulk Acoustic Standing Waves for Sheathless Focusing of Particles

Published on: March 6, 2016

Area of Science:

  • Biotechnology
  • Microfluidics
  • Cellular analysis

Background:

  • Conventional 2D microfluidic channels face limitations in particle confinement and precise velocity distribution.
  • Accurate particle positioning and velocity measurement are crucial for advanced cell analysis techniques.

Purpose of the Study:

  • To develop a microfluidic device capable of three-dimensional (3D) flow focusing and enhanced particle confinement.
  • To introduce a novel, equipment-light method for measuring individual particle velocities within microfluidic channels.

Main Methods:

  • Design and fabrication of a microfluidic device with a unique channel geometry (smaller sample channel, larger sheath flow channels).
  • Experimental demonstration of 3D flow focusing and particle confinement using beads and cells.
  • Development and application of a new method for individual particle velocity measurement compatible with flow cytometer setups.

Main Results:

  • The 3D microfluidic device achieved superior particle confinement compared to conventional 2D channels.
  • Significantly lower coefficients of variation (CVs) in velocity and position distributions were observed for both beads and cells.
  • A reduced probability of coincidental events was noted, enhancing analysis accuracy.
  • A novel, low-equipment method for individual particle velocity measurement was successfully demonstrated.

Conclusions:

  • The developed 3D microfluidic device offers enhanced particle confinement, crucial for improving microfluidic flow cytometers and fluorescence-activated cell sorting (FACS).
  • The novel particle velocity measurement method is compatible with existing flow cytometry setups and requires minimal specialized equipment.
  • The design principles and characterization methods are broadly applicable to various microfluidic systems.