Review of three magnetic resonance arthrography related infections

Andrew T Vollman1, Joseph G Craig, Rachel Hulen

  • 1Andrew T Vollman, Wayne State University School of Medicine, Detroit, MI 48202, United States.

Insights

Three patients developed joint infections after magnetic resonance arthrography. A multidisciplinary team identified oral contamination from prior barium swallow studies as a likely cause, prompting new safety protocols to prevent future arthrogram infections.

Area of Science:

  • Medical Imaging
  • Infectious Diseases
  • Radiology

Background:

  • Intra-articular infections are a potential complication following invasive procedures.
  • Magnetic resonance arthrography (MRA) involves injecting contrast material into a joint.
  • Previous studies have not extensively detailed infection risks associated with MRA.

Purpose of the Study:

  • To investigate the cause of three intra-articular infections following MRA.
  • To develop strategies for reducing infection risk related to arthrogram procedures.
  • To enhance patient safety in diagnostic imaging.

Main Methods:

  • Retrospective case review of three patients with post-MRA intra-articular infections.
  • Multidisciplinary team analysis involving radiology, infectious disease, and microbiology.
  • Evaluation of procedural workflows and potential sources of contamination.

Main Results:

  • Three cases of septic arthritis were confirmed post-MRA.
  • A common factor identified was the preceding barium swallow study in the same room.
  • Oral contamination from barium studies was proposed as the likely source of infection.

Conclusions:

  • Procedural contamination is a significant risk factor for MRA-related infections.
  • Implementing enhanced safety measures can mitigate the incidence of arthrogram infections.
  • Interdepartmental collaboration is crucial for identifying and addressing infection sources.