Related Experiment Video
Updated: May 13, 2026

Imaging of Biological Tissues by Desorption Electrospray Ionization Mass Spectrometry
Published on: July 12, 2013
Displaced dual-mode imaging with desorption electrospray ionization for simultaneous mass spectrometry imaging in
Christian Janfelt1, Niels Wellner, Harald S Hansen
1Department of Pharmacy, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark. christian.janfelt@sund.ku.dk
Abstract:
Displaced dual-mode imaging (DDI) is introduced as a method for simultaneous imaging in positive and negative-ion mode on the same sample with desorption electrospray ionization imaging, as well as a method for simultaneous imaging in full-scan and tandem mass spectrometry (MS/MS) mode. DDI is performed by using a smaller row distance in the y-direction than the desired image resolution and recording for example every second row in positive-ion mode and the other half of the rows in negative-ion mode, thus resulting in two separate images. This causes some degree of oversampling, which is thus utilized to obtain complementary mass spectrometric of the sample. Imaging with both polarities is exemplified on an imprint of a Hypericum perforatum leaf containing secondary metabolites which ionize in both polarites and a mouse kidney containing phospholipids which ionize in positive or negative mode only. Simultaneous full-scan and MS/MS imaging was demonstrated on the same mouse kidney, as the mouse had been given a relatively low dose of the antidepressive drug amitriptyline. While the full-scan data allowed imaging of the endogenous phospholipids, the drug and its metabolites were only visible in the MS/MS images. The latter approach is useful, for example in whole-body imaging experiments where the full-scan data gives an overview of the tissue, and the MS/MS mode provides the sensitivity to image trace amounts of drugs and metabolites.
More Related Videos
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
10:47Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization (IR-MALDESI)
Published on: March 24, 2016
Related Concept Videos
Tandem Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Matrix-Assisted Laser Desorption Ionization (MALDI)