Multidimensional gas chromatography using microfluidic switching and low thermal mass gas chromatography for the
1Australian Centre for Research on Separation Science ACROSS, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.
Abstract:
Volatile organic compounds such as light hydrocarbons, dienes, and aromatic compounds are often encountered in the manufacturing and processing environments of chemical and petrochemical segments. These compounds need to be closely monitored for process optimization, plant maintenance and industrial hygiene purposes. A high throughput analytical approach has been successfully developed and implemented for the accurate measurement of fourteen commonly encountered analytes. The approach incorporates a recently introduced 5-port planar microfluidic device configured for use as a Deans switch for multidimensional gas chromatography. The use of multidimensional gas chromatography allows the elimination of potential chromatographic contaminants with a substantial enhancement of stationary phase selectivity via the use of columns with different separation mechanisms, and the back-flushing of heavier undesired hydrocarbons. A low thermal mass gas chromatographic module was employed in the second dimension of the two-dimensional gas chromatography system and was used to provide independent temperature control, and rapid heating and cooling to meet the high throughput requirements. By successfully combining these concepts, complete analysis of fourteen targeted components can be conducted in less than 120s. Repeatability of retention times for all compounds was found to be less than 0.05% (n=20). Repeatability of area counts at two levels, namely 10ppmv and 1000ppmv over a period of two days was found to be less than 3% (n=20). Apart from methane, which has a detection limit of 0.4ppmv, the rest of the compounds were found to have detection limits of less than 0.2ppmv. Compounds of interest were found to be linear over a range of 500ppbv-3000ppmv with correlation coefficients greater than 0.999.
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...