Related Experiment Video
Updated: May 12, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Can scintillation detectors with low spectral resolution accurately determine radionuclides content of building
K Kovler1, Z Prilutskiy, S Antropov
1National Building Research Institute-Faculty of Civil and Environmental Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel. cvrkost@technion.ac.il
Abstract:
The current paper makes an attempt to check whether the scintillation NaI(Tl) detectors, in spite of their poor energy resolution, can determine accurately the content of NORM in building materials. The activity concentrations of natural radionuclides were measured using two types of detectors: (a) NaI(Tl) spectrometer equipped with the special software based on the matrix method of least squares, and (b) high-purity germanium spectrometer. Synthetic compositions with activity concentrations varying in a wide range, from 1/5 to 5 times median activity concentrations of the natural radionuclides available in the earth crust and the samples of popular building materials, such as concrete, pumice and gypsum, were tested, while the density of the tested samples changed in a wide range (from 860 up to 2,410 kg/m(3)). The results obtained in the NaI(Tl) system were similar to those obtained with the HPGe spectrometer, mostly within the uncertainty range. This comparison shows that scintillation spectrometers equipped with a special software aimed to compensate for the lower spectral resolution of NaI(Tl) detectors can be successfully used for the radiation control of mass construction products.
More Related Videos
08:53Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Determination of Crystal Structures
Gas Chromatography: Types of Detectors-II
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...