Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Enhanced external counterpulsation and CVD protection: 3D echo validation: a promising approach
H K Chopra1, C K Krishna, Ravinder S Sambi
1Department of Cardiology, Moolchand Medcity, New Delhi, India. drhkchopra@yahoo.com
Unlabelled:
AIMS & OBJECTIVE: To evaluate the impact of enhanced external counterpulsation (EECP) on various echo variables by 3D-Echocardiography.
Materials And Methods:
60 adult patients from indoor and outdoor patient department; consisting of 16 patients with heart failure (HF) with left ventricular systolic dysfunction, 20 patients with heart failure with normal ejection fraction (HFNEF), 4 patients with prior percutaneous coronary intervention (PCI), 3 patients with prior coronary artery bypass grafting (CABG) and 17 patients with syndrome X; were subjected to Echocardiographic evaluation. The various echo variables included were left ventricular myocardial performance index (LVMPI), left ventricular mass index (LVMi), left ventricular diastolic dysfunction (LVDD), left ventricular systolic function (LVEF) and left atrial volume index (LAVi). Once randomized, patients underwent 35 hrs EECP treatment sessions, each lasting 1 hour, could be given once or twice per day.
Results:
There was a significant reduction in the overall prolonged mean LVMPI from baseline (0.54 +/- 0.2) to post ECP treatment (0.43 +/- 0.1) in the total study population (p < 0.001). EECP treatment significantly reduced baseline grade II or grade III diastolic dysfunction and E/E' ratio > 12, but not in patients with baseline E/E' < 12, baseline normal diastolic function or grade I diastolic dysfunction. Similiarly the mean LVEF in the subset of patients with HF treatment was 30.7 +/- 3.1; post ECP the mean LVEF was increased to 36.9 +/- 3.2 which was statistically significant (p < 0.001). In the remaining patients, who had mean LVEF within normal range, there was no significant difference pre and post EECP (p value- NS). Pre EECP the mean LAVi in the total population was increased up to 33.4 +/- 5.6 ml/m2. Post EECP the mean LAVi reduced to 24.8 +/- 4.2 ml/m2, which was also statistically significant (p < 0.001). Regarding mean LVMi as well as in the patterns of LVH, there were no significant changes seen as compared to baseline.
Conclusion:
Enhanced External counterpulsation is noninvasive, non-surgical method of choice for CVD & heart failure protection. It is very useful in Single vessel or multivessel disease, heart failure, HFNEF, Post PCI or post CABG and syndrome X. It reduces LVMPI and improves global cardiac function, increases LVEF in patients with ejection fraction of less than 50%, reduces grade II or grade III diastolic dysfunction and E/E' ratio more than 12, decreases LAVi by 25.7%; thereby reducing adverse clinical events in CAD and heart failure.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...