Related Experiment Video
Updated: May 12, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
High-resolution diffusion-weighted imaging for monitoring breast cancer treatment response
Lisa J Wilmes1, Rebekah L McLaughlin, David C Newitt
1Department of Radiology and Biomedical Imaging, University of California, Box 1667, San Francisco, San Francisco, CA 94115, USA. lisa.wilmes@ucsf.edu
Rationale And Objectives:
The aim of this work was to compare a high-resolution diffusion-weighted imaging (HR-DWI) acquisition (voxel size = 4.8 mm(3)) to a standard diffusion-weighted imaging (STD-DWI) acquisition (voxel size = 29.3 mm(3)) for monitoring neoadjuvant therapy-induced changes in breast tumors.
Materials And Methods:
Nine women with locally advanced breast cancer were imaged with both HR-DWI and STD-DWI before and after 3 weeks (early treatment) of neoadjuvant taxane-based treatment. Tumor apparent diffusion coefficient (ADC) metrics (mean and histogram percentiles) from both DWI methods were calculated, and their relationship to tumor volume change after 12 weeks of treatment (posttreatment) measured by dynamic contrast enhanced magnetic resonance imaging was evaluated with a Spearman's rank correlation.
Results:
The HR-DWI pretreatment 15th percentile tumor ADC (P = .03) and early treatment 15th, 25th, and 50th percentile tumor ADCs (P = .008, .010, .04, respectively) were significantly lower than the corresponding STD-DWI percentile ADCs. The mean tumor HR-ADC was significantly lower than STD-ADC at the early treatment time point (P = .02), but not at the pretreatment time point (P = .07). A significant early treatment increase in tumor ADC was found with both methods (P < .05). Correlations between HR-DWI tumor ADC and posttreatment tumor volume change were higher than the STD-DWI correlations at both time points and the lower percentile ADCs had the strongest correlations.
Conclusion:
These initial results suggest that the HR-DWI technique has potential for improving characterization of low tumor ADC values over STD-DWI and that HR-DWI may be of value in evaluating tumor change with treatment.
More Related Videos
17:16Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
Published on: December 9, 2010
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012