Related Experiment Video
Updated: Aug 12, 2026

Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Evidence for an abnormal peripherally mediated vascular response to temperature in Raynaud's phenomenon
1University Department of Medicine, General Infirmary, Leeds.
Abstract:
It is unclear whether an abnormal vascular response to temperature change, independent of central sympathetic control, exists in Raynaud's phenomenon. We investigated this using the hyperaemic response to localized heating of dorsal foot skin, recorded by laser Doppler flowmetry. Fifteen normal adults, nine patients with primary, and seven with secondary Raynaud's phenomenon were studied. On warming, blood flow normally increases gradually at first, followed by rapid vasodilatation at temperatures above 33 degrees C. Normal geometric mean (95% confidence interval) blood flows at 33 degrees C and 36 degrees C were 0.19 (0.16-0.22) and 0.39 (0.29-0.53) arbitrary units respectively. In primary Raynaud's phenomenon, blood flows were 0.53 (0.44-0.62) and 1.07 (0.86-1.35) arbitrary units respectively (P less than 0.01 compared to normal subjects), showing early vasodilatation. Normal women have an intermediate response between men and primary Raynaud's patients. Responses in secondary Raynaud's phenomenon widely overlap the other groups. We conclude that an abnormal peripheral vascular response to temperature change exists in primary Raynaud's phenomenon.
Related Concept Videos
Thermosensation
Factors Affecting Body Temperature
Factors may include:
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation