Related Experiment Video
Updated: May 12, 2026

Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
Association of hemodilution and blood pressure in uncontrolled bleeding
Nicholas S Pawelczyk1, Maria del Pilar Huby, John R Salsbury
1Department of Surgery and Center for Translational Injury Research, University of Texas Health Science Center, Houston, Texas.
Background:
Hemodynamic status and coagulation capacity affect blood loss after injury. The most advantageous fluid and blood pressure to optimize resuscitation and minimize perturbation of coagulation are unclear. We investigated interactions of isovolumic hemodilution on hemodynamics, coagulation, and blood loss after injury.
Methods:
Twenty-five male rats were randomized into three groups (Whole Blood Uncontrolled Blood Pressure [WBU], n = 7; Lactated Ringers Uncontrolled Blood Pressure [LRU], n = 10; Whole Blood Controlled Blood Pressure [WBC], n = 8) with isovolumic hemodilution of 50% blood volume, with and without control of pre-injury blood pressure. All rats underwent uniform grade IV liver injury 30 min after serial exchanges. Post-injury blood loss and coagulation function were measured.
Results:
Dilution occurred, determined by hematocrit, with LRU having a greater reduction. Pre-injury mean arterial pressure (MAP) decreased compared with baseline (98 ± 7 mmHg) with LRU (62 ± 14 mmHg) and WBC (61 ± 10 mmHg), resulting in WBU (101 ± 13 mmHg) being significantly higher and not changed from baseline. Post-injury, MAP decreased from pre-injury, with LRU significantly lower than the other two groups. No differences were observed in prothrombin time/international normalized ratio or thromboelastography. Bleed volume was significantly different between groups: WBU < WBC < LRU and associated with the pre-injury MAP. Controlling baseline MAP, dilution with Lactated Ringers (LR) resulted in greater blood loss than whole blood (3.0 ± 0.4 versus 1.9 ± 0.3 mL).
Conclusions:
In this rat model of liver injury, blood loss was associated with baseline MAP and type of fluid used for dilution. Hemodilution with LR did not produce coagulopathy based on laboratory values. When controlling baseline MAP, dilution with LR increased bleeding, confirming a functional coagulopathic state.
Related Concept Videos
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Measurement of Blood Pressure
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart beats)...
Hypertension and Regulation of Blood Pressure
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.

