Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Online control of the twin-column countercurrent solvent gradient process for biochromatography
M Krättli1, F Steinebach, M Morbidelli
1Institute for Chemical and Bioengineering, ETH Zurich, CH-8093 Zurich, Switzerland.
Abstract:
A new control concept for the twin-column MCSGP process has been developed. The controller is based on two independent PID controllers each of which affects one side of the product collection window. Accordingly, the two controllers, although independent, can together shift the product collection along the elution chromatogram. The product stream collected during one entire process cycle is analyzed with an at-line HPLC allowing a direct feedback of the measured purity values to the controller. The two set points are given by the purity values with respect to weak and strong impurities in the product stream. The controller performance was tested with two systems: In the first one, a three component protein model mixture was considered. The controller stability and reliability was tested in conditions of both set point tracking and rejection of feed composition and pump flow rate disturbances. The complete experiment ran for 112h during which the desired purity values were always kept within the set points. A more realistic example was the purification of a monoclonal antibody supernatant from fragments and aggregates. In this case, the process reached specifications after five cycles, and kept them for 20h of operation in spite of ongoing disturbances in pump flow rates and feed composition. A new general start-up procedure was developed and tested in this particular purification process. The procedure starts from very simple initial conditions and let the controller to identify conditions, particularly for the recycle streams, which lead to yield and purity values significantly better than the corresponding values achieved in batch chromatography in specs.
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Principles Of Column Chromatography
Ion-Exchange Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
High-Performance Liquid Chromatography: Instrumentation