Background:
Numerous studies have demonstrated the accuracy of epiaortic ultrasound scanning (EAS) for assessing ascending aortic disease. It remains unclear whether EAS changes the incidence of perioperative stroke after off-pump coronary artery bypass (OPCAB).
Methods:
We studied a retrospective cohort of 2292 patients who underwent isolated OPCAB from January 2001 to December 2011. Patients were retrospectively subdivided into two groups: the non-EAS group (n=1019) who underwent OPCAB under only intraoperative transoesophageal echocardiography and the EAS group (n=1273) who underwent OPCAB under EAS.
Results:
In the non-EAS group, 317 (31.1%) patients underwent OPCAB with partial aortic clamping and 702 (68.9%) underwent OPCAB without partial aorta clamping. In the EAS group, 301 (23.7%) patients underwent OPCAB with partial aortic clamping and 972 (76.3%) underwent OPCAB without partial aortic clamping. The incidence of early stroke was not different statistically between the EAS and non-EAS groups [non-EAS 1.7% (17/1019) vs EAS 0.8% (10/1273); P=0.052]. However, in the subgroups of patients with partial aorta clamping, the incidence of the early stroke was significantly lower in the EAS group [2.8% (9/317) vs 0.7% (2/301) P=0.041].
Conclusions:
EAS has a significant clinical benefit in reducing the incidence of early stroke in cases of partial aortic clamping in OPCAB. Therefore, EAS should be considered in patients who need partial aortic clamping in OPCAB.
More Related Videos
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies