Can body surface microvolt T-wave alternans distinguish concordant and discordant intracardiac alternans?
Vincent Floré1, Piet Claus, Rolf Symons
1Department of Cardiovascular Diseases, Division of Experimental Cardiology, University of Leuven, Campus Gasthuisberg, Herestraat, Leuven, Belgium.
Introduction:
There is convincing experimental evidence that cellular action potential duration (APD) alternans is arrhythmogenic but its relationship with body surface microvolt T-wave alternans (MTWA) remains unclear. We investigated the relationship between MTWA and APD alternans induced by alternating cycle length (CL) pacing in a pig model.
Methods:
In 10 pigs, catheters in the right atrium (RA) and right (RV) and left ventricle (LV) allowed pacing and recording of monophasic action potentials (MAP). During RA pacing at stable 500-ms CL, LV was paced at alternating CL (505 ms and 495 ms). Changing the alternating LV (A-LV) pacing delay changes the size of the region with alternating ventricular activation. Spectral analysis of intracardiac MAP was correlated with body surface MTWA. In a similar setup (during alternating pacing in RV and LV), we investigated concordant versus discordant APD alternans.
Results:
Pacing the LV with subtle alternating cycle lengths at short A-LV delay leads to broad QRS (97 ± 10 ms), body surface MTWA (mean Valt 4.2 ± 1.8 µV), and positive RR-interval alternans. At longer A-LV delay, not resulting in QRS widening (68 ± 5 ms), body surface RR alternans was absent but MTWA remained detectable and was even more pronounced (8.7 ± 5.1 µV, P < 0.01). During both concordant and discordant pacing MTWA was present. The precordial leads were better for detecting discordant APD alternans (8.0 ± 2.9 µV and 12.8 ± 4.52 µV, P = 0.02).
Conclusion:
MTWA is a potent technique to detect subtle and isolated intracardiac APD alternans that is artificially induced by alternating pacing. In the same model, discordant activation alternans can only be discriminated from concordant when using a quantifying approach of MTWA analysis.
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias III: Characteristics of Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...