A Computerized Alert Screening for Severe Sepsis in Emergency Department Patients Increases Lactate Testing but does
T Berger1, A Birnbaum, P Bijur
1University of California , Davis, Sacramento, CA.
Applied Clinical Informatics
|April 26, 2013
Summary
A computer alert significantly increased lactate testing for emergency department sepsis patients. While more patients with elevated lactate levels were identified, in-hospital mortality for sepsis remained unchanged.
Area of Science:
- Emergency Medicine
- Critical Care Medicine
- Clinical Informatics
Background:
- Sepsis diagnosis in the emergency department (ED) relies on timely identification and testing.
- Systemic inflammatory response syndrome (SIRS) criteria, combined with clinical suspicion, are used to identify potential sepsis cases.
- Lactate testing is a crucial biomarker for assessing sepsis severity and guiding treatment.
Purpose of the Study:
- To evaluate the effectiveness of a computer-generated alert system in increasing lactate testing for ED sepsis patients.
- To assess the impact of the alert on identifying admitted sepsis patients with elevated lactate levels (≥4.0 mmol/L).
- To determine if the alert system influenced in-patient mortality rates among sepsis patients.
Main Methods:
- A 6-month pre-alert phase was followed by the implementation of a computer alert system.
- The alert system identified patients meeting ≥2 SIRS criteria and recommended lactate testing if infection was suspected.
- Data on lactate testing and patient outcomes were collected electronically for 6 months before and after alert implementation.
Main Results:
- Overall lactate testing in septic ED patients increased from 5.2% to 12.7% (p<0.001) after alert implementation.
- For admitted sepsis patients, lactate testing rose from 15.3% to 34.2% (p<0.001).
- A significant increase was observed in identifying admitted patients with lactate levels ≥4.0 mmol/L (1.9% absolute increase, p=0.05), while mortality showed a non-significant decrease (0.5%).
Conclusions:
- The computer alert system effectively enhanced lactate testing rates in the ED for sepsis patients.
- The alert system improved the identification of admitted sepsis patients with elevated lactate levels.
- In-patient mortality for sepsis patients did not change significantly following the implementation of the alert system.