Variable flip angle balanced steady-state free precession for lower SAR or higher contrast cardiac cine imaging
Subashini Srinivasan1, Daniel B Ennis
1Department of Bioengineering, University of California, Los Angeles, California, USA; Department of Radiological Sciences, University of California, Los Angeles, California, USA.
Purpose:
Cardiac cine balanced steady-state free precession (bSSFP) imaging uses a high flip angle (FA) to obtain high blood-myocardium signal-to-noise and contrast-to-noise ratios (CNR). Use of high FAs, however, results in substantially increased SAR. Our objective was to develop a variable FA bSSFP cardiac cine imaging technique with: (1) low SAR and blood-myocardium CNR similar to conventional constant FA bSSFP (CFA-bSSFP) or (2) increased blood-myocardium CNR compared to CFA-bSSFP with similar SAR.
Methods:
Variable FA bSSFP cardiac cine imaging was achieved using an asynchronous k-space acquisition, which is asynchronous to the cardiac cycle (aVFA-bSSFP). Bloch simulations and phantom experiments were performed to compare the signal, resolution, and frequency response of the variable FA bSSFP and CFA-bSSFP schemes. Ten volunteers were imaged with different aVFA-bSSFP and asynchronous CFA-bSSFP schemes and compared to conventional segmented CFA-bSSFP.
Results:
The SAR of aVFA-bSSFP is significantly decreased by 36% compared to asynchronous CFA-bSSFP (1.9 ± 0.2 vs. 3.0 ± 0.2 W/kg, P < 10(-10)) for similar blood-myocardium CNR (34 ± 6 vs. 35 ± 9, P = 0.5). Alternately, the CNR of the aVFA-bSSFP is improved by 28% compared to asynchronous CFA-bSSFP (49 ± 9 vs. 38 ± 8, P < 10(-4)) with similar SAR (3.2 ± 0.5 vs. 3.3 ± 0.5 W/kg, P = 0.6).
Conclusion:
aVFA-bSSFP can be used for lower SAR or higher contrast cardiac cine imaging compared to the conventional segmented CFA-bSSFP imaging.
Related Concept Videos
Cardiac Magnetic Resonance Imaging
In this video, high field, small-bore magnetic resonance imaging (MRI) with physiological monitoring is demonstrated to acquire gated cine loops of the murine cardiovascular system. This procedure provides a basis for assessing left-ventricular function, visualizing vascular networks, and quantifying motion of organs due to respiration. Comparable small animal...
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
09:14Cardiac Magnetic Resonance Imaging at 7 Tesla
07:02Phase Contrast Magnetic Resonance Imaging in the Rat Common Carotid Artery
06:31Real-time Imaging of Plant Cell Surface Dynamics with Variable-angle Epifluorescence Microscopy
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens