Related Experiment Video
Updated: May 11, 2026

E-Patient Counseling Trial (E-PACO): Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
CT colonography: preliminary assessment of a double-read paradigm that uses computer-aided detection as the first
Gabriella Iussich1, Loredana Correale, Carlo Senore
1Radiology Unit, Institute for Cancer Research and Treatment, FPO, Strada Provinciale 142, Km 3,95, 10060 Candiolo, Italy; im3D S.p.A., Turin, Italy. gabriella.iussich@ircc.it
Purpose:
To compare diagnostic performance and time efficiency of double-reading first-reader computer-aided detection (CAD) (DR FR CAD) followed by radiologist interpretation with that of an unassisted read using segmentally unblinded colonoscopy as reference standard.
Materials And Methods:
The local ethical committee approved this study. Written consent to use examinations was obtained from patients. Three experienced radiologists searched for polyps 6 mm or larger in 155 computed tomographic (CT) colonographic studies (57 containing 10 masses and 79 polyps ≥ 6 mm). Reading was randomized to either unassisted read or DR FR CAD. Data sets were reread 6 weeks later by using the opposite paradigm. DR FR CAD consists of evaluation of CAD prompts, followed by fast two-dimensional review for mass detection. CAD sensitivity was calculated. Readers' diagnoses and reviewing times with and without CAD were compared by using McNemar and Student t tests, respectively. Association between missed polyps and lesion characteristics was explored with multiple regression analysis.
Results:
With mean rate of 19 (standard deviation, 14; median, 15; range, 4-127) false-positive results per patient, CAD sensitivity was 90% for lesions 6 mm or larger. Readers' sensitivity and specificity for lesions 6 mm or larger were 74% (95% confidence interval [CI]: 65%, 84%) and 93% (95% CI: 89%, 97%), respectively, for the unassisted read and 77% (95% CI: 67%, 85%) and 90% (95% CI: 85%, 95%), respectively, for DR FR CAD (P = .343 and P = .189, respectively). Overall unassisted and DR FR CAD reviewing times were similar (243 vs 239 seconds; P = .623); DR FR CAD was faster when the number of CAD marks per patient was 20 or fewer (187 vs 220 seconds, P <01). Odds ratio of missing a polyp with CAD decreased as polyp size increased (0.6) and for polyps visible on both prone and supine scans (0.12); it increased for flat lesions (9.1).
Conclusion:
DR FR CAD paradigm had similar performance compared with unassisted interpretation but better time efficiency when 20 or fewer CAD prompts per patient were generated.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures II: Colonoscopy
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
