Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Magnetic susceptibility induced white matter MR signal frequency shifts--experimental comparison between Lorentzian
1Department of Radiology, Washington University, St. Louis, Missouri, USA.
Purpose:
The nature of the remarkable phase contrast in high-field gradient echo MRI studies of human brain is a subject of intense debates. The generalized Lorentzian approach (He and Yablonskiy, Proc Natl Acad Sci USA 2009;106:13558-13563) provides an explanation for the anisotropy of phase contrast, the near absence of phase contrast between white matter and cerebrospinal fluid, and changes of phase contrast in multiple sclerosis. In this study, we experimentally validate the generalized Lorentzian approach.
Theory And Methods:
The Generalized Lorentzian Approach suggests that the local contribution to frequency shifts in white matter does not depend on the average tissue magnetic susceptibility (as suggested by Lorentzian sphere approximation), but on the distribution and symmetry of magnetic susceptibility inclusions at the cellular level. We use ex vivo rat optic nerve as a model system of highly organized cellular structure containing longitudinally arranged myelin and neurofilaments. The nerve's cylindrical shape allowed accurate measurement of its magnetic susceptibility and local frequency shifts.
Results:
We found that the volume magnetic susceptibility difference between nerve and water is -0.116 ppm, and the magnetic susceptibilities of longitudinal components are -0.043 ppm in fresh nerve, and -0.020 ppm in fixed nerve.
Conclusion:
The frequency shift observed in the optic nerve as a representative of white matter is consistent with generalized Lorentzian approach but inconsistent with Lorentzian sphere approximation.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Atomic Nuclei: Magnetic Resonance
Magnetic Resonance Imaging
Magnetic Field due to Moving Charges
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...