Related Experiment Video
Updated: May 11, 2026

Trabecular Bone Microarchitecture Evaluation in an Osteoporosis Mouse Model
Published on: September 8, 2023
C-arm CT for histomorphometric evaluation of lumbar spine trabecular microarchitecture: a study on anorexia nervosa
C M Phan1, O Khalilzadeh, J Dinkel
1Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
Abstract:
Bone histomorphometry measurements require high spatial resolution that may not be feasible using multidetector CT (MDCT). This study evaluated the trabecular microarchitecture of lumbar spine using MDCT and C-arm CT in a series of young adult patients with anorexia nervosa (AN). 11 young females with AN underwent MDCT (anisotropic resolution with a slice thickness of ~626 μm) and C-arm CT (isotropic resolution of ~200 µm). Standard histomorphometric parameters the of L1 vertebral body, namely the apparent trabecular bone volume fraction (BV/TV), trabecular thickness (TbTh), trabecular number (TbN) and trabecular separation (TbSp), were analysed using MicroView software (GE Healthcare, Piscataway, NJ). Bone mineral density (BMD) was measured using dual-energy X-ray absorptiometry. Trabecular parameters derived from MDCT and C-arm CT were compared, and their association with BMD parameters was evaluated. Histomorphometric parameters derived from C-arm CT, namely TbTh, TbN and TbSp, were significantly different from the corresponding MDCT parameters. There were no significant correlations between C-arm CT-derived parameters and the corresponding MDCT-derived parameters. C-arm CT-derived parameters were significantly (p<0.001) correlated with anteroposterior L1 spine BMD and Z-scores: TbTh (r=0.723, r=0.744, respectively), TbN (r=-0.720, r=-0.712, respectively) and TbSp (r=0.656, r=0.648, respectively). BV/TV, derived from C-arm CT, was significantly associated with body mass index (r=0.636) and ideal body weight (r=0.730) (p<0.05). These associations were not present in MDCT-derived parameters. This study suggests that the spatial resolution offered by C-arm CT more accurately captures the histomorphometric parameters of trabecular morphology than MDCT in patients with AN.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
07:33Non-invasive Skeletal Muscle Quantification in Small Animals Using Micro-computed Tomography
Published on: November 8, 2024