Related Experiment Video
Updated: May 11, 2026

Application of a New Mesh Fixation Method in Laparoscopic Incisional Hernia Repair
Published on: December 23, 2022
Minimal incision transinguinal repair for incarcerated obturator hernia
Y Togawa1, T Muronoi, H Kawaguchi
1Department of Surgery, Kamitsuga General Hospital, 1-1033 Shimota-cho, Kanuma, Tochigi, Japan, tenriver@kamituga-hp.or.jp.
Background:
Patients with incarcerated obturator hernia are usually elderly, frail, and physically inactive women with serious comorbidities. Although a laparotomy is standard surgical intervention for emergency incarcerated or strangulated obturator hernia, it is invasive particularly for these high-risk patients. The aim of this study is to show the feasibility of minimum open inguinal approach to reduce surgical risk for preoperatively diagnosed incarcerated obturator hernia.
Methods:
Between April 2008 and July 2012, 3 consecutive incarcerated obturator hernia patients at Kamitsuga General Hospital who were diagnosed preoperatively by computed tomography underwent the following procedure. First a 4 cm inguinal hernia incision and preperitoneal dissection through the opening of the deep inguinal ring are made. The obturator hernia can be easily found 2 cm dorsally from the Cooper's ligament extraperitoneally. A small incision is made at medial sharp edge of the hernia defect. The hernia sac and its content can then be reduced. If the incarcerated bowel is viable, a prosthetic mesh is placed as a patch. If the bowel is necrotic, the damaged bowel loop is withdrawn through the wound and easily reconstructed extra-abdominally.
Results:
All operations were successfully completed with this procedure. All patients recovered without incident.
Conclusions:
Minimal incision transinguinal repair for diagnosed incarcerated obturator hernia is feasible and provides an improved option to more invasive procedures.