Related Experiment Video
Updated: May 11, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Application of PEEP using the i-gel during volume-controlled ventilation in anesthetized, paralyzed patients
Yong Beom Kim1, Young Jin Chang, Wol Seon Jung
1Department of Anesthesiology and Pain Medicine, Gachon University Gil Medical Center, 1198 Guwol-dong, Namdong-gu, Incheon, 405-760, Korea.
Purpose:
This prospective, randomized trial was designed to assess whether the i-gel supraglottic airway device is suitable for volume-controlled ventilation while applying positive end-expiratory pressure (PEEP) of 5 cmH(2)O under general anesthesia. It was believed that this device might improve arterial oxygenation.
Methods:
Forty adult patients (aged 20-60 years) scheduled for elective orthopedic surgery were enrolled in this study. Twenty patients were ventilated without external PEEP [zero positive end-expiratory pressure (ZEEP) group], and the other 20 were ventilated with PEEP 5 cmH(2)O (PEEP group) after placing an i-gel device. Volume-controlled ventilation at a tidal volume (TV) of 8 ml/kg of ideal body weight, leak volume, and arterial blood gas analysis were investigated.
Results:
The incidences of a significant leak were similar in the ZEEP and PEEP groups (3/20 and 1/20, respectively; P = 0.605), as were leak volumes. No significant PaO(2) difference was observed between the two groups at 1 h after satisfactory i-gel insertion (215 ± 38 vs. 222 ± 54; P = 0.502).
Conclusions:
The use of an i-gel during PEEP application at 5 cmH(2)O did not increase the incidence of a significant air leak, and a PEEP of 5 cmH(2)O failed to improve arterial oxygenation during controlled ventilation in healthy adult patients.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings