Abstract:
Seven different models of oxygen concentrators were purchased. The manufacturer's data were evaluated by a ranking method for operation at high temperature and high relative humidity, power consumption, warranty and cost. Measurements were then made of the oxygen concentration produced at maximum operating temperature. All the concentrators were CE marked and claimed compliance with the relevant Standard ISO 8359:1996. Only two models complied with their specification. On examination of the concentrators and the accompanying documents we found that compliance with 61 points listed in ISO 8359 ranged from 85% to 98%. Oxygen concentration was measured with the machines running simultaneously under both high temperature and high humidity. All models delivered low oxygen concentrations at 40 °C and 95% relative humidity. Only two models delivered >82% at 35 °C and 50% relative humidity. Concentrators intended for use in countries with limited resources should be evaluated before they are purchased, by independent experts, using the methods described herein.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.