Related Experiment Video
Updated: May 11, 2026

Rapid Quantification of Oxidized and Reduced Forms of Glutathione Using Ortho -phthalaldehyde in Cultured Mammalian Cells In Vitro
Published on: June 28, 2024
A new LC-MS/MS method for the clinical determination of reduced and oxidized glutathione from whole blood
Tereza Moore1, Anthony Le, Anna-Kaisa Niemi
1Department of Pathology, Stanford University School of Medicine, Stanford, CA 94305, United States.
Abstract:
Reduced levels of glutathione (γ-glutamylcysteinylglycine, GSH) and the ratio of GSH to glutathione disulfide (GSSG) can serve as important indicators of oxidative stress and disease risk. Measured concentrations of GSH and GSSG vary widely between laboratories, largely due to the instability of GSH during sample handling and variables arising from different analytical methods. We have developed a simple and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for measuring whole blood GSH and GSSG that minimizes preanalytic and analytic variability, reliably eliminates interference from ion suppression, and can easily be implemented in clinical laboratories. Samples were deproteinized with sulfosalicylic acid (SSA) and derivatized with N-ethylmaleimide (NEM) in a single preparative step, and the resulting supernatants combined with stable-isotope internal standards (GSH-(13)C, (15)N-NEM and GSSG-(13)C,(15)N), subjected to chromatographic separation using a Hypercarb column, and analyzed by MS/MS in the positive-ion mode. Results showed excellent linearity for both GSH and GSSG over the ranges of physiologic normal, with inter- and intra-assay CV's of 3.1-4.3% and accuracy between 95% and 101%. The lower limits of detection (LLOD) were 0.4μM for GSH and 0.1μM for GSSG and the lower limits of quantitation (LLOQ) were 1.5μM for GSH and 0.1μM for GSSG. Derivatized samples are stable for at least 3 years when stored at -80°C, and underivatized samples for at least 24h at either 4°C or room temperature. Reference intervals were determined for 59 control samples, and were (mean±SD): GSH 900±140μM; GSSG 1.17±0.43μM; GSH/GSSG 880±370.
More Related Videos
07:16Resin-Assisted Capture Coupled with Isobaric Tandem Mass Tag Labeling for Multiplexed Quantification of Protein Thiol Oxidation
Published on: June 21, 2021
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021