Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Fluence measurements employing iodide/iodate chemical actinometry as applied to upper-room germicidal radiation
1Department of Environmental Health, University of Alabama at Birmingham, Birmingham, Alabama, USA. rrahn1@nc.rr.com
Abstract:
To measure the fluence distribution in the upper room of a facility equipped with germicidal UV lamps a method has been developed utilizing iodide/iodate chemical actinometry together with spherical (1 cm) quartz irradiation chambers. The use of spherical vessels allows radiation from essentially all directions to be measured. Such a measurement allows an estimate of the radiation flux at a given point in space, i.e. the fluence rate. When a battery of spheres located at various points in a room are simultaneously irradiated, a measure of the fluence distribution can be obtained. The use of the iodide/iodate chemical actinometer is uniquely qualified to measure germicidal UV radiation. The purpose of this report is to provide details on how this system can be used to measure fluence rates. In particular, it describes how a hand-held colorimeter can be used to measure the absorbance changes in irradiated spheres.
More Related Videos
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Biological Effects of Radiation
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Flame Photometry: Lab
UV–Vis Spectrometers
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...