Differential scattering cross-sections for the different product vibrational States in the ion-molecule reaction

S Trippel1, M Stei, J A Cox

  • 1Center for Free-Electron Laser Science, DESY, Notke-Strasse 85, 22706 Hamburg, Germany.

Related Concept Videos

Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule01:10

Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule

In the AX proton spin system, proton A can sense the two spin states of a coupled proton X, resulting in a doublet NMR signal with two peaks of equal (1:1) intensity. When proton A is coupled to two equivalent protons (AX2 spin system), the spin states of each X can be aligned with or against the external field, creating three possible scenarios. This results in a 1:2:1  triplet signal, where the central peak corresponds to the chemical shift of A and is twice as large or intense as the others.
Mass Spectrometers01:16

Mass Spectrometers

This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
¹H NMR: Complex Splitting01:13

¹H NMR: Complex Splitting

A proton M that is coupled to a proton X results in doublet signals for M. However, NMR-active nuclei can be simultaneously coupled to more than one nonequivalent nucleus. When M is coupled to a second proton A, such as in styrene oxide, each peak in the doublet is split into another doublet.
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations01:08

IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations

Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single stretching vibration...